How to Use a Cavitation Machine (Helpful Instructions)

    If you're using an ultrasonic cavitation machine regularly but not getting visible results, it's because you're not using it properly. Only using the cavitation machine with the correct procedure will help you achieve your goals.

    In this detailed guide, we'll discuss how to use the ultrasonic cavitation machine with the proper method and all safety measures to achieve your desired body shape. Let's begin!

    Working principle of Cavitation Machine

    Ultrasonic cavitation machine works by delivering low-frequency sound waves to the targeted body area. The strong waves create bubbles in fat cells which burst and change the fat deposits into liquid form. The liquid form is eliminated from the body as waste. The result of the procedure is a reduction in fat and skin tightening. 

    Classification of Cavitation Machine

    Ultrasonic cavitation machines are classified into various types based on frequency range, power output, control, transducer types, safety features, portability, size, and adjustability. Mainly, there are low-intensity and high-intensity ultrasonic cavitation machines. Low-intensity machines operate at lower energy levels and are safer for sensitive body areas like the face and neck. These machines are commonly used in the weight loss and body contouring industry. Conversely, high-intensity machines can produce an intense cavitation effect and are suitable for powerful cavitation. However, they carry higher risks due to higher energy levels and power output.

    Normal Steps for using Cavitation Machine

    Here is the step-by-step method of using an ultrasonic cavitation machine that you must follow to maximize your results.

    • 1. First and foremost, select the appropriate machine and ensure it is in good working condition with all essential components.
    • 2. Clean the treatment area properly.
    • 3. Apply an ultrasonic gel evenly to the treatment area to protect the skin.
    • 4. Connect the machine to the power supply, sanitize its probe, and turn it on.
    • 5. Adjust the intensity according to the treatment area and the patient's tolerance. Start with lower energy and slowly increase if required.
    • 6. Start the treatment by moving the probe in small, circular motions on the treatment area. Ensure the probe is firmly pressed to the skin.
    • 7. Move it slowly at a consistent pace to evenly deliver the ultrasound energy.
    • 8. Monitor the patient and adjust the power if needed. Pay attention to any discomfort or skin redness and adjust intensity and time accordingly.
    • 9. The treatment time should be according to the targeted area and specific machine. Follow guidelines for recommended treatment duration.
    • 10. Once treatment is finished, clean the treatment area using a hot towel and clean the probe with a tissue. Lastly, follow post-treatment instructions for effective results.

    Cautions when using professional cavitation machine

    Safety should be the utmost factor while using professional cavitation machines. Unlike home ultrasonic cavitation machines, using professional cavitation machines requires crucial safety measures and instructions to follow.
    Here are the guidelines that help you understand how to properly use professional cavitation machines while staying safe to maximize results and minimize risks.

    1. Pay attention to the power and treatment time of the cavitation machine

    The power level and duration of using an ultrasonic cavitation machine play a crucial role in the safety and effectiveness of treatment. Before starting the treatment, you must thoroughly assess the client's body type and fat content and then adjust the power and time depending on the client's physical condition, treated area size, and skin type. The intensity should be as per the thickness of the fat layer and skin sensitivity.

     
    It is recommended to start the treatment with low power, then gradually increase it according to needs to avoid unnecessary risks. The higher the power, the shorter the procedure time to produce the cavitation effect. By tailoring the power and treatment time to individual clients' needs, you can benefit from the effectiveness and safety of a professional cavitation machine. 

    2. Avoid overtreatment

    Another essential thing to do while using a machine is to avoid overtreatment in one area. If the ultrasonic waves are applied at high intensity and over time in one area for too long, it can lead to skin burns, tissue damage, nerve damage, and discomfort. Therefore, avoid exceeding the recommended time and monitor the client's body response and tolerance to the intensity after each session.

    The procedure usually lasts between 20 to 60 minutes, depending on the treatment area and other factors.

    The average duration of treatment depends on targeted areas:
    Abdomen: 10-20 minutes
    Buttocks & thighs: 20-25 minutes
    Forearm: 5-10 minutes
    Back and shoulders: 20-40 minutes
    Besides safety, excessive treatment can affect the effectiveness of treatment, meaning the ideal results may not be achieved. Also, be sure to stay within the recommended number of treatments to prevent harmful side effects.

    3. Avoid movement during treatment to ensure client safety

    In addition to avoiding over-treatment, the operator should prevent movement during operation for the accuracy of treatment and client safety. Any activity can disrupt the effectiveness of treatment. Besides the operator, the client also needs to avoid even moving a little. Cavitation machines rely on focused energy and precise delivery of waves to the target area. Even a slight movement can hinder the machine's ability to reach the treatment area.


    It can also compromise patients' comfort & safety and increase the risk of accidental injuries. The provider can maintain treatment accuracy, increase overall treatment efficiency, and prioritize client safety by minimizing movement while using the cavitation machine.

    4. Professional operator for operation

    Only a trained person with an ultrasonic cavitation license and professional training should operate the machines. As a client, when you go for treatment, make sure your operator is licensed. Using professional cavitation machines for fat reduction and skin tightening requires in-depth knowledge of these machines that only experienced operators possess.

    Their knowledge and expertise help them make informed decisions regarding treatment durations, power settings, treatment plans, safety precautions, and more. When these machines are misused, they can pose serious complications. However, a trained operator knows the safety precautions to avoid these complications. They understand how to make a cavitation treatment a safe and comfortable experience for the client and correctly use the equipment to help the client achieve desired results.

    5. Must be checked and disinfected before use

    When choosing a professional cavitation machine, getting a reliable machine that meets industry quality standards is vital. Purchasing equipment from a reputable supplier guarantees the safety and accuracy of it. Most importantly, it is essential to thoroughly inspect and disinfect the cavitation machine before using it. Pretreatment inspection can help you identify any safety concerns, damaged parts, or abnormalities in equipment. By doing this, you can avoid the risk of accidents and guarantee optimal performance during treatments.

     
    Furthermore, cleaning and disinfection of the machine play a key role in maintaining a clean treatment environment and avoiding cross-contamination. These machines directly touch the skin during the operation, making it susceptible to contamination. Proper disinfection of machines before and after use can reduce the risk of transmitting infections among clients. Also, maintaining hygiene satisfies the client and shows your commitment to providing a safe treatment experience.

    6. Strictly comply with the instructions and safety procedures

    When it comes to properly using cavitation machines while ensuring safe treatment, operators should strictly follow instructions, safety procedures, and recommendations. The instruction manual outlines the treatment duration, intensity settings, machine maintenance, and other necessary techniques for achieving desired results. The effectiveness of ultrasonic cavitation treatment depends on the proper usage of the machine.

     
    Strictly adhering to these instructions means prioritizing clients' safety and maximizing treatment effectiveness. Ignoring these safety guidelines can result in serious effects. Therefore, the operators should follow these instructions to ensure safety and minimize potential risks. Additionally, it demonstrates professionalism and helps operators meet regulatory standards. If any unusual problems arise during the usage of these machines, the operator should stop the treatment and seek professional advice.

    7. Avoid use in unsuitable populations

    Ultrasonic cavitation machines aren't suitable for all people. Using caution and understanding the significance of avoiding cavitation machines in unsuitable people is vital. Operators should be aware of contraindications associated with cavitation machine treatments. These machines are not appropriate for pregnant, menstruation, and lactating women. Besides, individuals with medical conditions like kidney disease, liver disease, hypertension, diabetes, or heart conditions are unsuitable for ultrasonic cavitation treatments.

     
    Moreover, cavitation machines cannot be used on adolescents or young people. People with sensitive skin, recent surgery, or open wounds should avoid ultrasonic cavitation machine treatments. The intense waves and generated heat during the procedure can cause further irritation or infection. Also, cavitation machines are not so effective and suitable for people with relatively high or low Body Mass Indexes (BMI).

     
    Therefore, operators should evaluate the candidate's skin type and health before using the ultrasonic cavitation machine to ensure its safety and effectiveness. Additionally, they should tell clients about the limitations of cavitation machines and recommend any alternative method. By complying with these guidelines, operators can provide safe and effective treatments to suitable candidates.

    8. Assessment of the client's physical condition

    Assessing the client's medical history or physical condition before starting the ultrasonic cavitation machine treatment has the utmost significance. The pre-assessment allows providers to tailor the cavitation treatment to each individual's needs while ensuring the safety of the treatment and optimal results. Everyone's body is unique, and age, medical history, skin type, and overall health can affect the safety and effectiveness of cavitation treatments. Before using the cavitation machines, practitioners should identify contraindications and evaluate the treatment area.

     
    If the client has sensitive skin, injury, an open wound, or an infection in the treatment area, the machine must not be used for treatment in these areas. The heat and high-frequency waves can worsen the situation. Likewise, if the client has any medical condition, treatment must be postponed. One of the benefits of assessing the client's physical condition before utilizing the machine is that it gives a chance to do open and honest communication and discuss the results of ultrasonic cavitation machine treatments based on the client's health.


    In addition, it allows the operator to adjust the treatment parameters such as power settings, intensity, and target areas according to the client's unique condition. As a result, this approach enhances the effectiveness of treatment. Above all, pre-assessment is crucial to prioritize the client's safety while using these machines. By identifying contraindications or health concerns, providers can minimize potential risks and take precautions to avoid complications.

    9. Pay attention to discomfort symptoms.

    Another significant step to ensure patient safety and well-being while using professional cavitation machines is to continuously monitor patients during the operation. The provider should pay attention to client reactions and discomfort symptoms as early detection of serious effects during treatment. These effects include discomfort, pain, redness, swelling, or skin burns. If any of these signs occur, the doctor should stop the treatment and take immediate action or provide medical intervention to prevent further damage.

     
    Ultrasonic cavitation machines are well-tolerated, but they emit sound waves during the operation that can cause discomfort or pain to some clients. By attentively monitoring patients, the doctor can modify the power settings and intensity level to alleviate discomfort and optimize effectiveness. Besides, the patient can be provided with anesthetic cream before undergoing the treatment. Sometimes, adverse reactions occur, such as tissue damage due to excessive heating of tissue. By paying attention to patients, healthcare providers can address such complications and ensure patient safety throughout the treatment.


    Most importantly, the doctor should maintain open, effective communication with patients during the procedure. It encourages patients to express any discomfort or concerns and allows doctors to address them promptly to ensure patient safety. This level of care builds confidence in the doctor and creates a positive treatment experience for clients.

    10. Avoidance of post-treatment complications

    While the ultrasonic cavitation machine offers effective weight loss results, some post-treatment complications, such as bruising, pain, edema, and infection, may occur. Therefore, patients must avoid these complications by doing post-treatment care. The first and most important step in it is following the doctor's advice and instructions. After the treatment, the doctor provides specific aftercare instructions that the clients must follow. The instructions include recommendations for skin care, maintaining a healthy lifestyle, and avoiding certain products or activities.


    The client should stay hydrated during the recovery period to flush out fat cells and support the natural detoxification process. Ultrasonic cavitation treatment can make your skin more sensitive. So, it is recommended to protect the treated area from sun exposure for a few days after the session to avoid sunburn and hyperpigmentation. After the treatment, gently massage and moisturize the treated area to reduce swelling and promote lymphatic drainage.

     
    In addition, the client must maintain a healthy lifestyle by eating a balanced, nutrient-rich diet and doing regular moderate exercise. It is advisable to avoid intense workouts and other high-impact activities as they can strain the treated area. Rather take a rest to allow the body to heal properly. Following all these instructions will minimize the risk of post-treatment complications, promote smoother recovery, and help achieve the desired results.

    11. Regular maintenance and servicing

    Professional cavitation machines are high-tech devices that require regular maintenance and servicing by a professional provider for optimal performance of the machine and to provide a safe treatment experience. During the usage of the ultrasonic cavitation machine, the machine must be cleaned regularly to avoid the buildup of any oils, dirt, or residue. Clean the treatment heads and applicators as per the manufacturer's instructions. During installation, inspect the wires, connectors, and power cords for any signs of damage or loose connections. Replace the damaged parts and tighten the loose connections to avoid any unnecessary damage.

     
    Maintaining the efficiency of cavitation machines requires functional testing and calibration. Ask the manufacturer for instructions about performing these tasks. Functional testing ensures all settings, modes, and safety features are working properly. Calibration verifies precise energy delivery and maximized treatment accuracy. In addition, schedule regular professional servicing for comprehensive inspection and maintenance of your cavitation machines with a certified technician or manufacturer to address any issues.


    However, when the machine isn't in use, store it properly in a clean, dry environment. Regular maintenance and servicing of professional cavitation machines are necessary for their performance and the safety of patients.

    FAQ:

    1. Do I feel pain when I do the treatment?

    Do not. This treatment is painless.

    2. Is there any side effects after the treatment?

    When use it properly,there is no side effect after the treatment, safe and effective.

    3. Will I big noise in the ears during the treatment?

    We have overcome the problem of the buzzing in our ears. We have adopted the new technology called cavitation 2.0, which reduced 3 times of the noise when the ultrasound 40k cavitation probe working on the body which brings us a comfortable experience.

    4. Can I use the ultrasonic cavitation probe on my whole body?

    The ultrasonic cavitation has a strong wave which is with strong penetration. So it can not be used on the back and chest which are close to the organs.

    5. Should I exercise after the treatment?

    To maintain the result, keeping fit and doing exercise is required.

    You may like

    Change shipping country

    Cancel

    myChway.com ships to

    *Shop inUSD

    *Get shipping opitons for

    Change shipping Country

    GET A FREE QUOTE NOW

    close